This output was produced by an AskMojo lab. Build one that works for you.Create your own lab
Made withD4: the root causein8D ReportbyErwanErwanPUBLIC
DocumentAugust 18, 2026
AI-generated
SPEC8D Report › D4: the root cause

D4 root cause analysis, complaint CQ-4471

Erwan·August 18, 2026

Part 774-2210-B, batch L-26-0714. Written 2026-08-06.

Status in one line: occurrence cause CONFIRMED by measurement on retained samples. Escape cause CONFIRMED by document review. One secondary hypothesis remains OPEN and does not block D5.

01Hypothesis table, occurrence: why was the burr made
#HypothesisTest that would settle itDoneResultStatus
O1Deburring brush worn beyond useful life before its scheduled changeMeasure brush filament length on the removed brush against a new oneYes, 2026-08-03Removed brush 14 mm against 22 mm new, 36 percent loss. Trials on retained parts with a new brush produced no burrCONFIRMED
O2Bore diameter drift pushing material into the intersectionReview measurement log for the batch against toleranceYes, 2026-08-018.02 to 8.05 mm on a tolerance of 8.00 to 8.10. Centred, no driftRULED OUT, log ML-26-0714
O3Drill wear on the 8 mm operationTool life counter and drill inspectionYes, 2026-08-011 100 parts on a 4 000 part tool life. Drill within wear limit at inspectionRULED OUT, tool log CN06-T14
O4Material batch harder than nominalHardness check on retained raw materialNo, retained coupon not locatedNot testedOPEN

O4 stays OPEN. It is unlikely given that O1 is confirmed and reproduces the condition, but no test was run and it is not written off. Hardness check is scheduled 2026-08-14 on the next coil from the same supplier lot.

02Hypothesis table, escape: why did it get out
#HypothesisTest that would settle itDoneResultStatus
E1Control plan has no burr criterion on the 8 mm boreRead control plan CP-774-2210 rev CYes, 2026-07-30No burr characteristic listed. Bore diameter onlyCONFIRMED
E2Sampling too small to catch a 20 percent conditionSampling calculation against the observed rateYes, 2026-08-045 parts per box against an observed 20 percent gives roughly a 33 percent chance of catching it per box. Contributory, not primaryCONFIRMED, secondary
E3Inspector did not follow the control planReview inspection records and interview shift B inspectorYes, 2026-08-04Records complete and consistent with the plan. The plan itself did not ask for itRULED OUT, record IR-26-0714
03Five whys, confirmed occurrence branch
Why did the parts have a burr? The deburring brush was worn to 14 mm.
Why was it worn? It ran past its useful life inside its scheduled interval.
Why did the interval not catch it? The interval is time based, seven days, with no wear measurement at change.
Why is it time based? It was set when the machine ran a softer part at half the volume, and never revisited when 774-2210-B moved to CN-06 in March 2026.

Stop at four. The next why leaves what this company controls.

04Verdict
Occurrence: a brush wear interval set for a different part and volume, with no wear check to detect early wear. CONFIRMED.
Escape: the control plan carries no burr characteristic on the 8 mm bore, so no inspection could have caught it. Sampling size contributes. CONFIRMED.
Open: O4, raw material hardness. Test scheduled 2026-08-14. Does not block D5, which addresses both confirmed causes.
Share thisXLinkedInWhatsApp
Build your own with AskMojo

More from 8D Report

More by Erwan

Similar outputs

Knowledge bundle (OKF)